Libri GmbH Anesthesia Equipment Reference 2026-2027

Libri GmbH Anesthesia Equipment Reference 2026-2027

Tous les 1 prix et vendeurs

Choix le plus populaire – Meilleur prix !
Amazon.be· Vendeur reconnu
€ 110,62
3 à 4 joursLivraison gratuite
Check de website voor de levertijd | Gratis bezorgd > €20,-
Voir le produit
Voir le produit

Spécifications

Belangrijkste kenmerken
EAN
9798174196315

Description du produit

Trace Any Equipment Fault Back to Its Source Before It Reaches the Patient

This reference explains the machinery that stands between a clinician's intention and a patient's breath: medical gas supply, the workstation and its pressure zones, vaporizers, breathing systems and absorbents, ventilators, airway hardware, gas and physiologic monitoring, infusion technology, and the safety architecture around all of it. Thirty chapters build each device from its physics to its bedside behavior, then show precisely how it fails and what that failure looks like on the display in front of you. It is written for anesthesia technologists, residents, and nurse anesthetists expected to explain why the delivery system is misbehaving.

Every chapter carries The Fault Trace System: a five-part block that starts with the signal you actually see, traces it back through the physical system, names the fault, separates the look-alikes, and ends in one decisive action.

Inside this edition you will find:

- Gas physics applied to real hardware, including why a nitrous oxide gauge holds steady while the cylinder empties and why oxygen behaves differently
- Pipeline, manifold, and cylinder faults, so a crossover or supply failure is recognized while every pressure alarm on the machine stays silent
- Vaporizer physics, misfilling, tipping, and the pumping effect, so an agent monitor that disagrees with the dial tells you which direction of error you face
- Circle systems, unidirectional valves, and absorbent chemistry, separating exhausted absorbent from valve incompetence in two observations
- Ventilator drive mechanisms, modes, waveforms, and loops, using the peak-to-plateau difference to route a pressure alarm toward the apparatus or the chest
- Airway, monitoring, infusion, and ultrasound equipment, covering cuff pressure, sampling artifacts, damping, dead space, and the failures each produces
>Open it at the signal in front of you, follow the trace, and know what to do next.

Aucun avis n’a encore été écrit

Question 1 sur 4

Tu possèdes ce produit et tu aimerais donner ton avis ? Commence ci-dessous à écrire ton avis. Selon le niveau de détail, écrire un avis prend en moyenne entre 3 et 10 minutes. Avec ton opinion, tu aides les autres visiteurs à faire un meilleur choix et tu tentes chaque mois de gagner 250 € ! Clique ici pour les conditions de l’action.

Quelle note donnes-tu à ce produit ?